Atex Explosion Protected Triple Zener Barrier Zener3
The Triple Zener Barrier Zener3 is a “three barriers in one” solution for the connection between a weighing terminal and a weight receiver system in the ATEX ZONE. This “3 in 1” feature protecting the excitation line, signal and sense which makes installation much easier.
See further under the Product Information tab.
-
Type: Triple Zener Barrier Zener3 Price: On application
-
Type: HZ3 Description: ATEX ABS housing kit HZ3 with Zener Barrier Price: On application
ATEX Triple Zener Barrier Zener3
- Equipped with 3 channels for the protection of the Signal line (CN1/CN4), the Excitation line (CN3/CN6) and the Sense line, for improved signal stability.
- Temperature of usage: -20°C ÷ +60°C.
- Storage temperature: -25°C ÷ +70°C
- Rating: 14Vrms differential and 8Vrms through earth for CN3 connector, 20Vrms for the CN1 & CN2
- Maximum Security Voltage(Um): 250Vrms
- Maximum Security Current (current interruption capability): 1500A
- Degree of protection: IP20
- Excitation, Signal and Sense Marking: ATEX II (1)G, II(1)D, I(M1)
- Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20°C ≤ Tamb ≤ +60°C)
ATEX Housing kit HZ3 with Triple Zener Barrier
ATEX ABS housing kit HZ3 with Zener Barrier for load cells. For intrinsically safe weighing systems in an explosive zone.
- material: ABS
- overall housing dimensions 180 x 180 x 150 mm
- connectivity for up to 4 load cells of 350 Ohm
- 4 glands, ATEX certified
- protection for case + barrier:
– ATEX II 3(1) Ex Na [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for Gas
– ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for Dust.
Scale types: Atex single weighing components