Single Point Aluminum Load Cell LA104
Model LA104 is available in capacities of 150 – 3000 g. It is a very accurate single point loadcell with very high precision, designed for direct assembly in precision weighing scales with low weighing capacity, such as gold and jewelery scales, analytical balances, medical weighing equipment, etc.
See further under the tab Product information.
-
Type: LA104-150g Weighing capacity: 150 g Price: On application
-
Type: LA104-200g Weighing capacity: 200 g Price: On application
-
Type: LA104-300g Weighing capacity: 300 g Price: On application
-
Description: LA104-600g Weighing capacity: 600 g Price: On application
-
Type: LA104-1200g Weighing capacity: 1200 g Price: On application
-
Type: LA104-1500g Weighing capacity: 1500 g Price: On application
-
Type: LA104-3000g Weighing capacity: 3000 g Price: On application
Single Point Aluminum Load Cell LA104
- capacities from 150 to 3000 g
- up to 100,000 divisions short term precision at room temperature
- maximum platform size 200 x 200 mm at 3000 divisions
- IP66 protection class
- error better than 0.0048% of Rated Output available
- a 3 mm threaded hole in the loading end of the load cell is provided for overload protection
- can be used as a replacement for type 1004
Applications
Model LA104 is a very low capacity, very high precision single point load cell designed for direct mounting in low capacity scales and precision balances.
This load cell is ideal for applications including gold and jewelry scales, analytical balances, medical equipment, medical and pharmaceutical research and low level force measurement.
Specifications
PARAMETER | UNIT | VALUE | ||||||||||
Rated capacity (Emax) | g | 150, 200, 300, 600, 1200, 1500, 3000 | ||||||||||
Sensitivity | mV/V | 0.90 | ||||||||||
Sensitivity tolerance | ± mV/V | 0.10 | ||||||||||
Zero balance | ± mV/V | 0.10 | ||||||||||
Y=Emax/vmin | Typical | 4000 | ||||||||||
Z=Emax/(2*DR) | Typical | 3000 | ||||||||||
Creep (From stable to 2min) | ± % | 0.0085 | ||||||||||
Temperature effect on output | ± %/ C | 0.0014 | ||||||||||
Hysteresis | % | 0.0080 | ||||||||||
Linearity deviation | % | 0.0120 | ||||||||||
Repeatability | % | 0.0090 | ||||||||||
Eccentric loading error | ±%/cm | 0.0042 | ||||||||||
Maximum platform size | mm | 200 x 200 | ||||||||||
Nominal temperature range | °C | -10 to +40 | ||||||||||
Service temperature range | °C | -30 to +70 | ||||||||||
Limit load | % of R.C. | 200 | ||||||||||
Break load | % of R.C. | 300 | ||||||||||
Nominal Humidity Range | %RH | 20 to 65 | ||||||||||
Nominal excitation | V | 5 | ||||||||||
Max. excitation | V | 15 | ||||||||||
Input impedance | Ohm | 410 ± 15 | ||||||||||
Output impedance | Ohm | 350 ± 3 | ||||||||||
Insulation resistance | MOhm | >2000 | ||||||||||
Cable length | Meter | 0.35 | ||||||||||
Cable type | 4 conductors, 28 AWG, Aluminum foil Shielded, Black PVC Jacket | |||||||||||
Color code |
|
|||||||||||
Construction | Aluminum Alloy | |||||||||||
Compensation circuit type | Balanced Bridge | |||||||||||
Protection class to IEC529 | IP 66 |
Scale types: Load cells, Single Point Load Cells, Weighing components