Single Point Load Cell LA490-B
High performance, high capacity single point load cell designed for direct mounting of large weigh platforms. The rugged construction offers high immunity to side forces making it suitable for a wide range of weighing applications, including bench scales, check weighing and process weighing.
The LA-490B provides scale manufacturers with a high accuracy low cost sensor to meet today’s needs.
See further under the Product Information tab.
-
Type: LA490-B-50kg Description: Single point load cell Weighing capacity: 50 kg Price: On application
-
Type: LA490-B-75kg Description: Single point load cell Weighing capacity: 75 kg Price: On application
-
Type: LA490-B-100kg Description: Single point load cell Weighing capacity: 100 kg Price: On application
-
Type: LA490-B-150kg Description: Single point load cell Weighing capacity: 150 kg Price: On application
-
Type: LA490-B-200kg Description: Single point load cell Weighing capacity: 200 kg Price: On application
-
Type: LA490-B-250kg Description: Single point load cell Weighing capacity: 250 kg Price: On application
-
Type: LA490-B-500kg Description: Single point load cell Weighing capacity: 500 kg Version: Verifiable Price: On application
-
Type: LA490-B-635kg Description: Single point load cell Weighing capacity: 500 kg Version: Verifiable Price: On application
Single Point Load Cell LA490-B
- CE-verifiable capacities: 50, 75, 100, 150, 200, 250, 500 and 635 kg
- version anodised aluminium
- protection class IP 66
- accuracy class C3
- for weighing platforms up to and included 600 x 600 mm
- can be used as a replacement for type 1260
- see further leaflet
TECHNICAL DATA
PARAMETER | UNIT | VALUE | ||||||||||||||
OIML Accuracy | C3 | |||||||||||||||
Rated capacity (Emax) | kg | 50, 75, 100, 150, 200, 250, 500, 635 | ||||||||||||||
Sensitivity | mV/V | 2.00 | ||||||||||||||
Sensitivity tolerance | ± mV/V | 0.20 | ||||||||||||||
Zero balance | ± mV/V | 0.10 | ||||||||||||||
Maximum Number of Intervals | 3000 | |||||||||||||||
Y=Emax/vmin | Minimum | 10000 | ||||||||||||||
Z=Emax/(2*DR) | Minimum | 3000 | ||||||||||||||
Eccentric loading error | ±%/cm | 0.0042 | ||||||||||||||
Maximum platform size | cm | 60×60 | ||||||||||||||
Nominal temperature range | °C | -10 to +40 | ||||||||||||||
Service temperature range | °C | -30 to +70 | ||||||||||||||
Limit load | % of R.C. | 150 | ||||||||||||||
Break load | % of R.C. | 300 | ||||||||||||||
Nominal excitation | V | 10 | ||||||||||||||
Max. excitation | V | 15 | ||||||||||||||
Input impedance | Ohm | 406 ± 15 | ||||||||||||||
Output impedance | Ohm | 350 ± 3 | ||||||||||||||
Insulation resistance | MOhm | >2000 | ||||||||||||||
Compensation circuit type | Balanced Bridge | |||||||||||||||
Cable length | Meter | 3.0 | ||||||||||||||
Cable type | 6×26 AWG, Black PVC Jacket | |||||||||||||||
Color code |
|
|||||||||||||||
Construction | Anodised Aluminum Alloy | |||||||||||||||
Protection class to IEC529 | IP 66 |
Scale types: Load cells, Single Point Load Cells, Weighing components